Non-contacting transmitters, VdS Cl. B and C
EKOM 11 i
Electr. non-contacting transmitter, suitable for insulation displacement technology LSA. For recess mounting. Transmitter and receiver with inductive signal and energy transmission. Connection for alarm-wire, glassbreak detectors and magnetic contacts.
Notes
| EKOM 11 i with glassbreak detector: The EKOM 11 i may be used for monitoring a window, a french window, a door or a gate (incl. wicket door). Contact capacity: Max. 24 V DC, 200 mA, 300 mW; Transmission power: < 0.15 µW; Transmission frequency: 140 kHz and 280 kHz ± 5 kHz |
|---|
Downloads
Attributes
| Approvals | G 117507: Opening state monitoring, VdS Class B |
|---|---|
| Cable dimensions | Ø 3.8 mm |
| Cable length brown | 4 m |
| Cable length white | 4 m, 6 m, 10 m |
| Connection cable | LIYY 6 x 0.14 mm² Cu tinned |
| Housing | 68 x 29.3 x 10 mm |
| Housing material | A-B-S |
| Inner conductor | 4 black, 1 red, 1 blue |
| Lateral mounting-misal. | Max. 3 mm |
| Mounting distance transmitter - receiver | Max. 20 mm ± 2 mm |
| Operating current triggered | Max. 18 mA at 12 V DC |
| Operating voltage | 12 V DC (tolerance 9–15 V DC) |
| Outputs | electronic switch |
| Parallel capacity | app. 10 nF |
| Protection category | VdS environmental class III, IP67 |
| Stand-by current | app. 4 mA at 12 V DC (max. 6 mA) |
| Temperature range | -25 °C to +70 °C |
| Transfer resistance | app. 5 Ω |